Please use this identifier to cite or link to this item:
http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1304
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Leyton, Fernando | - |
dc.contributor.author | Nogueira, Maria do Socorro | - |
dc.contributor.author | Dantas, Marcelino | - |
dc.contributor.author | Duran, Maria Paz | - |
dc.contributor.author | Ubeda, Carlos | - |
dc.date.accessioned | 2018-02-21T18:49:49Z | - |
dc.date.available | 2018-02-21T18:49:49Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Leyton, F. et al. Mean glandular dose in six digital mammography services in Santiago, Chile: preliminary reference. Radiation Protection Dosimetry, v.165, n-1-4, p.115-120, 2015. | pt_BR |
dc.identifier.issn | 1742-3406 | pt_BR |
dc.identifier.uri | http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1304 | - |
dc.description.abstract | The purpose of this paper was to estimate mean glandular dose levels (DG) in six digital mammography systems in Santiago, Chile, and to propose preliminary reference levels to execute mammography in Chile. The study was carried out assessing two direct digital systems and four computer-based radiography (CR) systems. Estimates of DG were calculated for different thicknesses of polymethyl methacrylate according to the quality control protocol in digital mammography of the Spanish Society of Medical Physics and NHSBSP Equipment Report 0604 Version 3. DG values ranged between 0.64 and 7.26 mGy for a range of 20- to 70-mm thickness, respectively. Thirty-six per cent of DG was higher than the acceptable dose level and 100 % of DG was higher than the desirable level. It is therefore necessary to optimise doses. The initial proposal to establish dose reference levels for DG would range between 0.90 and 6.40 mGy for a thickness range of 20 to 70 mm | pt_BR |
dc.format.extent | 115-120 | pt_BR |
dc.language.iso | en_US | pt_BR |
dc.rights | L | pt_BR |
dc.subject | Mammary glands | pt_BR |
dc.subject | Radiation doses | pt_BR |
dc.subject | Biomedical radiography | pt_BR |
dc.title | Mean glandular dose in six digital mammography services in Santiago, Chile: preliminary reference | pt_BR |
dc.type | Artigo Periódico | pt_BR |
dc.coverage | I | pt_BR |
dc.creator.affiliation | Diego Portales University, Santiago, Chile | pt_BR |
dc.creator.affiliation | Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil | pt_BR |
dc.creator.affiliation | Industrias Nucleares do Brasil—INB, Caldas, Brazi | pt_BR |
dc.creator.affiliation | Clínica Alemana, Santiago, Chile | pt_BR |
dc.creator.affiliation | Tarapaca University, Arica, Chile | pt_BR |
dc.identifier.fasciculo | 1-4 | pt_BR |
dc.identifier.vol | 165 | pt_BR |
dc.title.journal | Radiation Protection Dosimetry | pt_BR |
Appears in Collections: | Artigo de periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Mean glandular dose in six digital mammography services in Santiago.pdf | 119.93 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.