Please use this identifier to cite or link to this item:
http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1290
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Guimarães, Margarete C. | - |
dc.contributor.author | Silva, C.R.E. | - |
dc.contributor.author | Oliveira, P.M.C. | - |
dc.contributor.author | Silva, Teógenes Augusto da | - |
dc.date.accessioned | 2018-02-07T13:09:18Z | - |
dc.date.available | 2018-02-07T13:09:18Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Guimarães, M.C., Silva, C.R.E., Oliveira, P.M.C., Da Silva, T.A. On the response of electronic personal dosimeters in constant potential and pulsed x- ray beams Journal of Physics: Conference Series, v.733, n.1, art. no. 012094, 2016. | pt_BR |
dc.identifier.issn | 17426588 | pt_BR |
dc.identifier.uri | http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1290 | - |
dc.description.abstract | Electronic personal dosimeters (EPDs) based on solid state detectors have widely been used but some deficiencies in their response in pulsed radiation beams have been reported. Nowadays, there is not an international standard for pulsed x-ray beams for calibration or type testing of dosimeters. Irradiation conditions for testing the response of EPDs in both the constant potential and pulsed x-ray beams were established in CDTN. Three different types of EPDs were tested in different conditions in similar ISO and IEC x-ray qualities. Results stressed the need of performing additional checks before using EPDs in constant potential or pulsed x-rays. | pt_BR |
dc.format.extent | 012094 | pt_BR |
dc.language.iso | en_US | pt_BR |
dc.rights | L | pt_BR |
dc.subject | Dosimetry | pt_BR |
dc.subject | Personnel | pt_BR |
dc.subject | Radiation detectors | pt_BR |
dc.title | On the response of electronic personal dosimeters in constant potential and pulsed x- ray beams | pt_BR |
dc.type | Artigo Periódico | pt_BR |
dc.coverage | I | pt_BR |
dc.creator.affiliation | Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil | pt_BR |
dc.creator.affiliation | Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil | pt_BR |
dc.creator.affiliation | Universidade Federal de Minas Gerais, UFMG, Belo Horizonte, MG, Brasil | pt_BR |
dc.creator.affiliation | Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil | pt_BR |
dc.identifier.fasciculo | 1 | pt_BR |
dc.identifier.vol | 733 | pt_BR |
dc.title.journal | Journal of Physics: Conference Series | pt_BR |
Appears in Collections: | Artigo de periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
On the response of electronic personal dosimeters.pdf | 1.08 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.