Use este identificador para citar ou linkar para este item: http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1310
Título: Dosimetry andimagequalityindigitalmammographyfacilities in theStateofMinasGerais,Brazil
Título do periódico: Radiation Physics and Chemistry
Autor(es): Silva, Sabrina Donato da
Joana, Geórgia Santos
Oliveira, Bruno Beraldo
Oliveira, Marcio Alves de
Leyton, Fernando
Nogueira, Maria do Socorro
Afiliação: Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil
Universidade Federal de Minas Gerais, UFMG, Belo Horizonte, MG, Brasil
Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil
Universidade Federal de Uberlândia, UFU, Uberlância, MG
Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil
Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil
Data do documento: 2015
Palavras-chave: Mammary glands;Dosimetry;Quality control
Resumo: AccordingtotheNationalRegisterofHealthCareFacilities(CNES),thereareapproximately477mam- mographysystemsoperatinginthestateofMinasGerais,Brazil,ofwhichanestimated200aredigital apparatus usingmainlycomputerizedradiography(CR)ordirectradiography(DR)systems.Mammo- graphyisirreplaceableinthediagnosisandearlydetectionofbreastcancer,theleadingcauseofcancer death amongwomenworldwide.Ahighstandardofimagequalityalongsidesmallerdosesandopti- mization ofproceduresareessentialifearlydetectionistooccur.Thisstudyaimedtodeterminedosi- metry andimagequalityin68mammographyservicesinMinasGeraisusingCRorDRsystems.Thedata of thisstudywerecollectedbetweentheyearsof2011and2013.Thecontrast-to-noiseratioprovedtobe a criticalpointintheimageproductionchainindigitalsystems,since90%ofserviceswerenotcompliant in thisregard,mainlyforlargerPMMAthicknesses(60and70mm). Regardingtheimagenoise,only31%ofthesewerecompliant.Theaverageglandulardosefoundisof concern, sincemorethanhalfoftheservicespresenteddosesaboveacceptablelimits.Therefore,despite the potentialbenefits ofusingCRandDRsystems,theemploymentofthistechnologyhastoberevised and optimizedtoachievebetterqualityimageandreduceradiationdoseasmuchaspossible.
Acesso: L
Aparece nas coleções:Artigo de periódico

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dosimetry andimagequalityindigitalmammographyfacilities in theStateofMinasGerais Brazil.pdf718.37 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.