Título: Spectra transmitted by Mortar barite in x-ray qualities applied in diagnostic radiology as shielding
Título do periódico: Journal of Physics: Conference Series
Autor(es): Almeida, Airton T.
Araújo, F. G S
Nogueira, Maria Do Socorro
Santos, M. A.P.
Afiliação: Universidade Federal de Ouro Preto, UFOP, Ouro Preto, MG, Brasil
Universidade Federal de Ouro Preto, UFOP, Ouro Preto, MG, Brasil
Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil
Centro Regional de Ciências Nucleares, NE, Recife, PE, Brasil
Data do documento: 2016
Palavras-chave: Barite;Radiation protection;Shielding;X ray spectra
Resumo: Concrete which contains water, cement and aggregate, is widely used in building construction such as medical hospitals. The CdZnTe spectrometry system was used to acquire the transmitted spectra in the RQR qualities and the stripping procedure was performed by taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined. The samples were prepared in rectangular plate format with dimensions of (5 x 5) cm with thicknesses varying from 0.2cm to 2cm and exposed to x-ray beams generated. The HVL and the mean energy in this energy range was determined.
Acesso: L
Aparece nas coleções:Artigo de periódico

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Spectra transmitted by mortar barite.pdf1.47 MBAdobe PDFVisualizar/Abrir