Title: | Traceability from governamental producers of radiopharmaceuticals in measuring 18F in Brazil |
Title of periodic: | Applied Radiation and Isotopes |
Authors: | Oliveira, A.E. Iwahara, A. Silva, C.J. Cruz, P.L. Poledna, R. Silva, R.L. Laranjeira, A.S. Delgado, J.U. Tauhata, L. Loureiro, J.S. Toledo, B.C. Braghirolli, A.M.S. Andrade, E.A.L. Silva, J.L. Hernandes, H.O.K. Valente, Eduardo Sarmento Dalle, Hugo Moura Almeida, V.M. Silva, T.G. Fragoso, M.C.F. Oliveira, M.L. Nascimento, E.S.S. Oliveira, E.M. Herrerias, R. Souza, A.A. Bambalas, E. Bruzinga, W.A. |
Affiliation: | Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Radioproteção e Dosimetria, IRD, Rio de Janeiro, RJ, Brasil Instituto de Engenharia Nuclear, IEN, Rio de Janeiro, RJ, Brasil Instituto de Engenharia Nuclear, IEN, Rio de Janeiro, RJ, Brasil Instituto de Engenharia Nuclear, IEN, Rio de Janeiro, RJ, Brasil Instituto de Engenharia Nuclear, IEN, Rio de Janeiro, RJ, Brasil Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil Centro Regional de Ciências Nucleares, CRCN-NE, Recife, PE, Brasil Centro Regional de Ciências Nucleares, CRCN-NE, Recife, PE, Brasil Centro Regional de Ciências Nucleares, CRCN-NE, Recife, PE, Brasil Centro Regional de Ciências Nucleares, CRCN-NE, Recife, PE, Brasil Instituto de Pesquisas Energéticas e Nucleares, IPEN, São Paulo, SP, Brasil Instituto de Pesquisas Energéticas e Nucleares, IPEN, São Paulo, SP, Brasil Instituto de Pesquisas Energéticas e Nucleares, IPEN, São Paulo, SP, Brasil Instituto de Pesquisas Energéticas e Nucleares, IPEN, São Paulo, SP, Brasil Instituto de Pesquisas Energéticas e Nucleares, IPEN, São Paulo, SP, Brasil |
Issue Date: | 2016 |
Keywords: | Nuclear medicine;Radiopharmaceuticals;Drugs |
Abstract: | Since the inception of its proficiency test program to evaluate radionuclide measurement in hospitals and clinics, the National Metrology Laboratory of Ionizing Radiation-LNMRI, that represents Brazilian National Metrology Institute (NMI) for ionizing radiation has expanded its measurement and calibration capability. Requirements from the National Health Surveillance Agency from Ministry of Health (ANVISA), to producers of radiopharmaceuticals provided an opportunity to improve the full traceability chain to the highest level. Fluorodeoxyglucose (FDG-18F) is the only radiopharmaceutical simultaneously produced by all Brazilian radiopharmaceutical production centers (RPCs). By running this proficiency test, LNMRI began to provide them with the required traceability. For evaluation, the ratio of RPC to reference value results and ISO/IEC17043:2010 criteria were used. The reference value established as calibration factor on the secondary standard ionization chamber was obtained from three absolute measurements systems, and routinely confirmed in each round of proficiency test by CIEMAT/NIST liquid scintillation counting. The γ-emitting impurities were checked using a High-Purity Germanium (HPGe) detector. The results show that Brazilian RPCs are in accordance with (accuracy within 710%) the Brazilian standard for evaluation of measurements with radionuclide calibrators (CNEN NN 3.05., 2013). Nevertheless, the RPCs should improve the methodology of uncertainty estimates, essential when using the statistical criteria of ISO/IEC 17043 standard, in addition to improving accuracy to levels consistent with their position in the national traceability chain |
Access: | L |
Appears in Collections: | Artigo de periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Traceability from governamental producers of radiopharmaceuticals.pdf | 410.04 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.