Please use this identifier to cite or link to this item:
http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1240
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Silva, Teógenes Augusto da | - |
dc.contributor.author | Guimarães, Margarete C. | - |
dc.contributor.author | Meireles, Leonardo S. | - |
dc.contributor.author | Teles, Luciana L.D. | - |
dc.contributor.author | Lacerda, Marco Aurélio Sousa | - |
dc.date.accessioned | 2018-01-18T12:25:18Z | - |
dc.date.available | 2018-01-18T12:25:18Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Silva, T.A.da, et al. Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility. Applied Radiation and Isotopes, v.117, p. 70-73, 2016 | pt_BR |
dc.identifier.issn | 0969-8043 | pt_BR |
dc.identifier.uri | http://www.repositorio.cdtn.br:8080/jspui/handle/123456789/1240 | - |
dc.description.abstract | A new regulatory statement was issued concerning the eye lens radiation protection of persons in planned exposures. A debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to establish the individual monitoring procedure with the EYE-D™ holder and a MCP-N LiF:Mg,Cu,P thermoluminescent chip detector for measuring the personal dose equivalent Hp(3) in workers of a Positron Emission Tomography Radiopharmaceutical Production Facility. | pt_BR |
dc.format.extent | 70-73 | pt_BR |
dc.language.iso | en_US | pt_BR |
dc.rights | R | pt_BR |
dc.subject | Calibration | pt_BR |
dc.subject | Dosimeters | pt_BR |
dc.subject | Eyes | pt_BR |
dc.subject | Lenses | pt_BR |
dc.subject | Cylindrical configuration | pt_BR |
dc.subject | Radiation doses | pt_BR |
dc.subject | Positron computed tomography | pt_BR |
dc.title | Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility | pt_BR |
dc.type | Artigo Periódico | pt_BR |
dc.coverage | I | pt_BR |
dc.creator.affiliation | Centro de Desenvolvimento da Tecnologia Nuclear, CDTN, Belo Horizonte, MG, Brasil | pt_BR |
dc.identifier.vol | 117 | pt_BR |
dc.title.journal | Applied Radiation and Isotopes | pt_BR |
Appears in Collections: | Artigo de periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Reliability of eye lens dosimetry.pdf | 737.39 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.